The BK5120 “Economy plus” Bus Coupler connects the CAN bus system to the electronic terminal blocks, which can be extended in modular fashion. One unit consists of one Bus Coupler, any number of up to 64 terminals and one end terminal. With the K-bus extension technology, the BK5120 allows the connection of up to 255 spatially distributed Bus Terminals to one Bus Coupler.
| Technical data | BK5120 |
|---|---|
| Number of Bus Terminals | 64 (255 with K-bus extension) |
| Max. number of bytes fieldbus | 16 Tx/Rx PDOs |
| Digital peripheral signals | 960 inputs/outputs |
| Analog peripheral signals | 60 inputs/outputs |
| Configuration possibility | via KS2000 or the controller |
| Number of PDOs (CANopen) | 16 Tx/16 Rx |
| Additional CANopen features | life, node guarding, emergency object, variable mapping, store/restore |
| Data transfer rates | up to 1 Mbaud |
| Bus interface | 1 x open style connector, 5-pin, included |
| Power supply | 24 V DC (-15 %/+20 %) |
| Input current | 70 mA + (total K-bus current)/4, 500 mA max. |
| Starting current | approx. 2.5 x continuous current |
| Recommended fuse | ≤ 10 A |
| Current supply K-bus | 1750 mA |
| Power contacts | 24 V DC max./10 A max. |
| Electrical isolation | 500 V (power contact/supply voltage Bus Coupler) |
| Weight | approx. 150 g |
| Operating/storage temperature | -25…+60 °C/-40…+85 °C |
| Relative humidity | 95 %, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. | IP 20/variable |
| Approvals | CE, UL, Ex, GL |
| Accessories | |
|---|---|
| KS2000 | configuration software for extended parameterisation |
| Cordsets | cordsets and connectors |
| FC5101 | FC5102 | CANopen PCI fieldbus cards |
| Related products | |
|---|---|
| BK5110 | CANopen Coupler for up to 64 digital Bus Terminals |
| BK5150 | CANopen “Compact” Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension) |
| BK5151 | CANopen “Compact” Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension) |
| LC5100 | CANopen “Low Cost“ Bus Coupler version for up to 64 digital Bus Terminals (255 with K-bus extension) |
| BC5150 | CANopen “Compact” Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension) |
| BX5100 | CANopen Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension) |
| CX8051 | CANopen Embedded PC, slave |
BK5120 CANopen Bus Coupler, BK5150, BK5151, LC5100 Beckhoff
- IBA-AG
- Okazaki
- Spohn Burkhardt
- Schenck process
- DMN-WESTINGHOUSE
- Nireco
- Redlion
- Matsushima
- KELLER ITS
- FOTOELEKTRIK PAULLY
- MINIMAX
- GASTRON
- Sitec components
- CEG Elettronica
- Teclock
- Mark-10
- AT2E
- Beckhoff
- Kiepe
- Ohkura
- KNICK
- Koganei
- IPF Electronic
- TDK Lambda
- DAIICHI Electric
- As Schoeler
- CS instruments
- RIELS
- INTORQ
- SAUTER
- COMET SYSTEM
- CEMB
- ASHCROFT
- KROHNE
- TEK-TROL
- KRACHT
- UNIPULSE
- Fox thermal
- VELJAN
- BRONKHORST
- Hirose Valve
- Russell Finex
- HIFLUX FILTRATION
- LABOM
-
MỘT SỐ HÃNG KHÁC PHÂN PHỐI
- COMAV srl
- ELCO
- JIANGYIN FUXIN
- STI VIBRATION MONITORING
- Merrick Industries
- Finetek
- HS-Cooler
- YOUNG TECH
- Baumueller
- PILZ
- KOMETER
- Bircher
- Ametek Land
- BURKERT
- ELAU
- Suntes
- Temavasconi
- Beijer Electronics
- AEGPS
- environsupply
- Stellar Technology
- BARKSDALE
- Conductix
- CEIA
- SIMEX
- EURO SWITCH
- SENSOREX
- Arjay
- Novotechnik
- Wise Control
- ROTORK
- Agrichema
- PULS
- Det-tronics
- Cisco
- Prosoft
- NEODYN
- MTL
- Versa
- KEYSTONE-PENTAIR
- CATERPILLAR
- Masibus
- POTECH
- Woodward
- Vacuum Barrier
- Tridonic
- Fairport
- Ebmpapst
- Firetrol
- Hyoda
- CELEM
- JINDA
- Seojin instech
- ECDI
- Wittenstein
- SOLDO
- Pro-Face
- Vee Bee Filtration
- Hans Hennig
-
Trực tuyến:4
-
Hôm nay:548
-
Tuần này:4787
-
Tháng trước:17874
-
Tất cả:2475509
.jpg)